| Contactor assembly Star-delta (wye-delta) (pre-assembled) with timing relay on the front AC-3, 5.5 kW/400 V, 3-pole Size S00, S00, S00 Electrical and mechanical interlock, Screw terminal 24 V DC !!! Phased-out product !!! Successor is SIRIUS 3RA2 Preferred successor type is >>3RA2415-8XF31-1BB4<< |
Product brand name | SIRIUS |
Product designation | contactor assembly |
Size of contactor | S00, S00, S00 |
Product function | wye-delta-contactor |
Product extension Auxiliary switch | Yes |
Insulation voltage with degree of pollution 3 rated value | 690 V |
Degree of pollution | 3 |
Protection class IP on the front | IP20 |
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | K |
Reference code acc. to DIN EN 81346-2 | Q |
Reference code acc. to DIN EN 61346-2 | Q |
Installation altitude at height above sea level maximum | 2 000 m |
Ambient temperature | |
during operation | -25 ... +60 °C |
during storage | -55 ... +80 °C |
during transport | -55 ... +80 °C |
Number of poles for main current circuit | 3 |
Number of NC contacts for main contacts | 0 |
Operating voltage at AC-3 rated value maximum | 690 V |
Operating current | |
at AC-3 at 400 V rated value | 12 A |
Operating power at AC-3 | |
at 400 V rated value | 5.5 kW |
at 500 V rated value | 7.2 kW |
at 690 V rated value | 9.2 kW |
Type of voltage of the control supply voltage | DC |
Control supply voltage 1 | |
at DC rated value | 24 V |
Operating range factor control supply voltage rated value of magnet coil at DC | |
initial value | 0.8 |
Full-scale value | 1.1 |
Operating range factor control supply voltage rated value of magnet coil at AC | |
at 50 Hz | 0.8 ... 1.1 |
at 60 Hz | 0.85 ... 1.1 |
Design of the surge suppressor | without |
Control version of the switch operating mechanism | conventional |
Number of NC contacts for auxiliary contacts lagging switching | 0 |
Number of NO contacts for auxiliary contacts | |
instantaneous contact | 2 |
leading contact | 0 |
Design of the fuse link for short-circuit protection of the main circuit | |
with type of coordination 1 required | fuse gL/gG: 35 A |
with type of assignment 2 required | fuse gL/gG: 20 A |
Mounting position | with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back |
Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 |
Height | 71 mm |
Width | 135 mm |
Depth | 148 mm |
Required spacing | |
with side-by-side mounting at the side | 0 mm |
for grounded parts at the side | 0 mm |
for live parts | |
— at the side | 0 mm |
Type of electrical connection for main current circuit | screw-type terminals |